Sikalastic®-560 is a cold-applied, one-component waterborne liquid applied waterproofing membrane, highly elastic and UV resistant.
- One-component - ready to use
- Cold applied - requires no heat or flame
- Seamless waterproofing membrane
- UV resistant and UV stable
- Highly elastic and crack-bridging
- Easily recoated when needed - no stripping required
- Economic – provides a cost efficient life cycle extension for failing roofs
- Low VOC emitting water-based coating
- Excellent adhesion on porous and non-porous substrates
- Water vapour permeable - allows the substrate to breathe
- 12 months shelf life

Usage
- For roof waterproofing solutions in both new construction and refurbishment projects
- For roofs with many details and complex geometry when accessibility is limited
- For cost efficient life cycle extension of failing roofs
- For reflective coating to enhance energy efficiency by reducing cooling costs
Advantages
- One-component - ready to use
- Cold applied - requires no heat or flame
- Seamless waterproofing membrane
- UV resistant and UV stable
- Highly elastic and crack-bridging
- Easily recoated when needed - no stripping required
- Economic – provides a cost efficient life cycle extension for failing roofs
- Low VOC emitting water-based coating
- Excellent adhesion on porous and non-porous substrates
- Water vapour permeable - allows the substrate to breathe
- 12 months shelf life
Packaging
4 kg plastic pails
20 kg plastic pails
Colour
Grey, White and Green (Available only 20 kg pail)
Product Details
ENVIRONMENTAL INFORMATION
- Conformity with LEED v2009 IEQc 4.2: Low-Emitting Materials - Paints and Coatings
- Conformity with LEED v2009 SSc 7.2 (Option 1): Heat Island Effect - Roof
APPROVALS / STANDARDS
- Fulfils initial solar reflectance requirements acc. Energy Star (0.820)
- Meets requirements of external fire performance ENV 1187 BRoof (T1) on non-combustible substrates
-
Certified Green Label product under Singapore Green Labelling Scheme (SGLS) in accordance to Singapore Environmental Council (SEC) Green Label Category 32: Paint and Surface Coating
Chemical Base
Polyurethane modified acrylic dispersion
Shelf Life
12 months from date of production if stored properly in original, unopened and undamaged sealed packaging.
Storage Conditions
The product must be stored properly in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +30 °C.
Higher storage temperatures may reduce shelf life of product.
Reference shall also be made to the storage recommendations within the safety data sheet.
Density
~1.35 kg/L (+23 °C) | (EN ISO 2811-1) |
Solid content by weight
~65 % (+23 °C / 50 % r.h.)
Solid content by volume
~48 % (+23 °C / 50 % r.h.)
System Structure
Roof Coating*
Sikalastic®-560 is applied in 2 or 3 coats
Total consumption | ≥ 0.9 - 1.4 kg/m2 |
Dry film thickness | ≥ 0.3 - 0.5 mm |
*For partial reinforcement Sikalastic® Fleece-120 is applied at areas with high movement, irregular substrate or to bridge cracks, joints and seams on the substrate as well as for details. On bitumen felt a fully reinforced roof waterproofing system has to be applied.
For primer, please refer to the Substrate Pre-Treatment table below.
Reinforced Roof Waterproofing
Sikalastic®-560 is applied in 1 coat, reinforced with Sikalastic® Fleece-120 or Sika®-120 Reemat and sealed with 1 - 2 coats of Sikalastic®-560
Layer | Product | Consumption |
1. Primer | please refer to substrate pre-treatment | please refer to substrate pre-treatment |
2. Base coat | Sikalastic®-560 | ≥ 1.0 - 1.5 kg/m2 |
3. Reinforcement | Sikalastic® Fleece-120 or Sika®-120 Reemat | - |
4. Top coats | Sikalastic®-560 applied in 1-2 coats | ≥ 1.1 - 1.3 kg/m2 |
Note: Do not apply more than 0.75 kg/m2 of Sikalastic®-560 per coat for layers without reinforcement.
Note: These figures are theoretical and do not include for any additional material required due to surface porosity, surface profile, variations in level and wastage.
Tensile Strength
Not reinforced | ~1.5 N/mm2 |
Reinforced with Sikalastic® Fleece-120 | ~12 N/mm2 |
Solar Reflectance
0.821) | (ASTM C 1549) |
1)All values refer to the inital (properly cured, non-weathered) status of Sikalastic®-560 white.
Thermal Emittance
0.931) | ASTM E 408 |
1)All values refer to the inital (properly cured, non-weathered) status of Sikalastic®-560 white.
Solar Reflectance Index
1021) | (ASTM E 1980) |
1)All values refer to the initial (properly cured, non-weathered) status of Sikalastic®-560 white.
Service Temperature
With Fleece | Without Fleece |
-10 °C min. / +80 °C max. | -5° C min. / +80 °C max. |
Application
Ambient Air Temperature
+8 °C min. / +35 °C max.
Relative Air Humidity
80 % r.h. max.
Substrate Temperature
+8 °C min. / +35 °C max.
≥3 °C above dew point
Substrate Moisture Content
≤ 6 % pbw
No rising moisture according to ASTM (Polyethylene-sheet).
Waiting Time / Overcoating
Waiting time with Sikalastic® Fleece | Waiting time without Sikalastic® Fleece | Ambient condition |
24 h | 6 h | +20 °C / 50 % r.h. |
12 h | 4 h | +30 °C / 50 % r.h. |
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.
Applied Product Ready for Use
Touch dry | Rain resistant | Full cure | Ambient condition |
2 hour approx. | 8 hours approx. | 4 days approx. | +20 °C / 50 % r.h. |
1 hour approx. | 4 hours approx. | 2 days approx. | +30 °C / 50 % r.h. |
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.
SUBSTRATE PREPARATION
The surface must be sound, of sufficient strength, clean, dry and free of dirt, oil, grease and other contamination. Depending on the material the substrate must be primed or mechanically cleaned. Grinding may be necessary to level the surface.
Suitable substrates are such as: concrete, bituminous felts and coatings, metal, brickwork, asbestos cement, ceramic tiles, wooden substrates.
Prime the substrate and always use a reinforced system.
- Brick and stone: Mortar joints must be sound and preferably flush pointed. Use localized reinforcement over joints and prime before applying Sikalastic®-560.
- Slates, Tiles, etc.: Ensure all slates/tiles are sound and securely fastened, replacing obviously broken or missing sections. Fully glazed tiles must be abraded prior to priming and subsequent treatment with Sikalastic®-560.
- Bituminous Felt: Ensure that bituminous felt is firmly adhered or mechanically fixed to the substrate. Bituminous felt should not contain any badly degraded areas. Prime and always use a totally reinforced system.
- Bituminous Coatings: Bituminous coatings should not have sticky or mobile surfaces, volatile mastic coatings, or old coal tar coatings. Prime and always use a totally reinforced system.
- Metals: Metals should be in sound condition. Abrade the exposed surfaces to reveal bright metal. Use locally reinforcement over joints and fixings.
- Wooden substrates: Timber and timber based panel roof decks are to be in good condition, firmly adhered, or mechanically fixed.
- Paints/Coatings: Ensure the existing material is sound and firmly adhered. Remove any oxidized layers and use localized reinforcement over joints.
MIXING
Prior to application, stir Sikalastic®-560 thoroughly for 1 minute in order to achieve a homogeneous mixture.
Over mixing must be avoided to minimise air entrainment.
APPLICATION
Prior the application of Sikalastic®-560 the priming coat if used must have cured tack-free. For the Waiting Time / Overcoating please refer to the PDS of the appropriate primer. Damageable areas (door frame) have to be protected with an adhesive tape
Roof Coating: Sikalastic®-560 is applied in two or three coats. Prior to the application of a 2nd coat the indicated waiting time in the table above shall be allowed.
Roof Waterproofing: Sikalastic®-560 is applied in combination with Sikalastic® Fleece 120 or Sika®-120 Reemat.
- Apply first coat of approx. 0.75 kg/m2 (for non-absorbing substrates) – 1.00 kg/m2 (for absorbing substrates) of Sikalastic®-560 on a length of approx. 1m.
- Roll in the Sikalastic® Fleece-120 or Sika®-120 Reemat and ensure that there are no bubbles or creases. Overlapping of the fleece minimum 5 cm.
- Apply second coat of approx. 0.25 kg/m2 - 0.5kg/m2 coat right into the wet fleece to achieve the required film thickness. The entire application shall happen while Sikalastic®-560 is still liquid, wet in wet.
- Repeat step 1–3 until the roof area is waterproofed.
- After the two coats are dry, seal the roof area with one or more additional coats of Sikalastic®-560 (≥ 0.5 kg/m² per coat).
Please note, always begin with details prior starting with waterproofing the horizontal surface.
CLEANING OF TOOLS
Clean all tools and application equipment with water immediately after use. Hardened / cured material can only be removed mechanically.